Abstract
Domain shift poses significant problems to computer-aided diagnostic (CAD) systems when deployed in clinical scenarios. There’s still no definite fix nor there is an in-depth understanding of the exact factors driving domain shifts in medical X-rays. Here, we conduct an exploratory study on three covariate shift factors in X-ray classification by controlling for different variables.
This is possible by leveraging a homogenously-relabelled mix of public and private X-ray data spanning 23 medical institutions over four continents and for 17 classes of pathologies. We show that the acquisition parameter, device manufacturer, and geographical shifts degrade out-of-distribution (OOD) F1 by 6%, 3.2% and 3.3%, respectively. Pneumothorax was found to be the most impaired pathology, suffering a mean F1 generalization gap of 13.3%, despite being one of the most clinically-consequential radiological findings.
To this end, we introduced LISA-topK, a multi-label adaptation of Learning Invariant Predictors with Selective Augmentation (LISA), which we showed to narrow down the OOD gap, surpassing other methods consistently. These pragmatic results shed light on some of the elements of OOD generalization in X-ray classification, which are essential to researching, understanding, and deploying CAD systems.
The code is available through Github, HERE.
Excited to explore further? Send us an email at [email protected].